Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
Bridges are subjected to temperature loads due to climatic action. However, Colombia lacks its own studies to quantify the design values of temperature loads on bridges. Consequently, in this work the objective is to monitor the surface temperature of a concrete bridge and it is carried out on the v...
Saved in:
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Trabajo de grado (Pregrado y/o Especialización) |
Language: | spa |
Published: |
Universidad Antonio Nariño
2023
|
Subjects: | |
Online Access: | http://repositorio.uan.edu.co/handle/123456789/7532 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1812647046009585664 |
---|---|
author | Rodriguez Estrada, Manuel Angel Gallo Martinez, Juan David |
author2 | Osorio Bustamante, Edison |
author_facet | Osorio Bustamante, Edison Rodriguez Estrada, Manuel Angel Gallo Martinez, Juan David |
author_sort | Rodriguez Estrada, Manuel Angel |
collection | DSpace |
description | Bridges are subjected to temperature loads due to climatic action. However, Colombia
lacks its own studies to quantify the design values of temperature loads on bridges.
Consequently, in this work the objective is to monitor the surface temperature of a concrete
bridge and it is carried out on the vehicular bridge of the First of May with Boyacá Avenue in
Bogotá. Monitoring is carried out by measuring temperatures with a thermal camera at dawn and
midday, for 15 days in two seasons of the year. Surface temperature data is presented at the top
and bottom of the dashboard, providing values for future analysis and model calibration. In
addition, a transient thermal balance model is performed using the finite difference method with
hourly environmental data. The results are compared with the measurements, and it is concluded
that the model can be a tool to reproduce the thermal phenomenon for future analyses |
format | Trabajo de grado (Pregrado y/o Especialización) |
id | repositorio.uan.edu.co-123456789-7532 |
institution | Repositorio Digital UAN |
language | spa |
publishDate | 2023 |
publisher | Universidad Antonio Nariño |
record_format | dspace |
spelling | repositorio.uan.edu.co-123456789-75322024-10-09T22:41:31Z Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. Rodriguez Estrada, Manuel Angel Gallo Martinez, Juan David Osorio Bustamante, Edison Cargas térmicas diferencias finitas, efectos térmicos - cámara térmica T48.23 R696e Thermal loads finite differences thermal effects - thermal camera Bridges are subjected to temperature loads due to climatic action. However, Colombia lacks its own studies to quantify the design values of temperature loads on bridges. Consequently, in this work the objective is to monitor the surface temperature of a concrete bridge and it is carried out on the vehicular bridge of the First of May with Boyacá Avenue in Bogotá. Monitoring is carried out by measuring temperatures with a thermal camera at dawn and midday, for 15 days in two seasons of the year. Surface temperature data is presented at the top and bottom of the dashboard, providing values for future analysis and model calibration. In addition, a transient thermal balance model is performed using the finite difference method with hourly environmental data. The results are compared with the measurements, and it is concluded that the model can be a tool to reproduce the thermal phenomenon for future analyses Los puentes están sometidas a cargas de temperatura por la acción climática. Sin embargo, para Colombia faltan estudios propios para cuantificar los valores de diseño de cargas por temperatura en los puentes. En consecuencia, en este trabajo se plantea como objetivo el monitoreo de la temperatura superficial de un puente de concreto y se realiza sobre el puente vehicular de la Primera de Mayo con Avenida Boyacá en Bogotá. El monitoreo se efectúa midiendo las temperaturas con cámara térmica en horas del amanecer y del mediodía, durante 15 días en dos épocas del año. Se presentan los datos de temperatura superficial en la parte superior e inferior del tablero, aportando valores para futuros análisis y calibración de modelos. Además, se realiza un modelo transitorio de balance térmico mediante el método de diferencias finitas con datos ambientales horarios. Los resultados se comparan con las mediciones y se concluye que el modelo puede ser una herramienta para reproducir el fenómeno térmico para futuros análisis. Ingeniero(a) Civil Pregrado Presencial Monografía 2023-02-14T19:58:53Z 2023-02-14T19:58:53Z 2022-11-30 Trabajo de grado (Pregrado y/o Especialización) info:eu-repo/semantics/acceptedVersion http://purl.org/coar/resource_type/c_7a1f http://purl.org/coar/version/c_970fb48d4fbd8a85 http://repositorio.uan.edu.co/handle/123456789/7532 American Association of State Highway and Transportation Officials AASTHO-98 AASHTO, 2016. (2016). Knovel—AASHTO LRFD Bridge Design Specifications, U.S. Customary Units with 2015 and 2016 Interim Revisions (7th Edition). https://app.knovel.com/kn/resources/kpAASHTO6E/toc American National Standard Data Format for Radiation Detectors Used for Homeland Security—Redline. (2020). ANSI N42.42-2020 (Revision of ANSI N42.42-2012) - Redline, 1-311. Chile.cubica. (2017). Patologías en Construcción. chilecubica. http://www.chilecubica.com/patologías/ Díaz Barreiro, Patricia. (2014). Protocolo para los estudios de patología de la construcción en edificaciones de concreto reforzado en Colombia. https://repository.javeriana.edu.co/handle/10554/12694 Ding, K., Hu, P., & Xia, D. (2010). Research on Type Selection of Highway Bridge Composite Expansion and Contraction Installation. 2010 International Conference on E-Product E-Service and E-Entertainment, 1-4. https://doi.org/10.1109/ICEEE.2010.5660383 Google Maps. (2022). Google Maps. https://www.google.com/maps/@4.6188565,- 74.1400352,3a,75y,118.45h,84.62t/data=!3m7!1e1!3m5!1s6XTAlJ2pPVCEklKtXnv4kA!2e0!6s https:%2F%2Fstreetviewpixelspa.googleapis.com%2Fv1%2Fthumbnail%3Fpanoid%3D6XTAlJ2pPVCEklKtXnv4kA%26cb_cl ient%3Dmaps_sv.tactile.gps%26w%3D203%26h%3D100%26yaw%3D199.06444%26pitch%3D 0%26thumbfov%3D100!7i16384!8i8192 Heng, L., & Huarui, G. (2018). Analysis of Longitudinal Cracking for Hollow-core Slab Bridges. 2018 3rd IEEE International Conference on Intelligent Transportation Engineering (ICITE), 68-73. https://doi.org/10.1109/ICITE.2018.8492703 IDEAM. (2018). Consulta y Descarga de Datos Hidrometeorológicos. http://dhime.ideam.gov.co/atencionciudadano/ Invias. (2020). A partir de hoy, Gobierno Nacional pone en funcionamiento el Puente Hisgaura en Santander. https://www.invias.gov.co/index.php/sala/noticias/3655-a-partir-de-hoygobierno-nacional-pone-en-funcionamiento-el-puente-hisgaura-en-santander Liu, H. (2020). Sensitivity of Seismic Response of the Steel-Concrete Plate Composite Beam Bridge with Transverse Supported Steel Beams to Design Parameters. 2020 International Conference on Intelligent Transportation, Big Data & Smart City (ICITBS), 205-209. https://doi.org/10.1109/ICITBS49701.2020.00050 instname:Universidad Antonio Nariño reponame:Repositorio Institucional UAN repourl:https://repositorio.uan.edu.co/ spa Acceso abierto Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) https://creativecommons.org/licenses/by-nc-nd/4.0/ info:eu-repo/semantics/openAccess http://purl.org/coar/access_right/c_abf2 application/pdf application/pdf application/pdf Universidad Antonio Nariño Ingeniería Civil Facultad de Ingeniería Civil Bogotá - Sur |
spellingShingle | Cargas térmicas diferencias finitas, efectos térmicos - cámara térmica T48.23 R696e Thermal loads finite differences thermal effects - thermal camera Rodriguez Estrada, Manuel Angel Gallo Martinez, Juan David Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. |
title | Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. |
title_full | Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. |
title_fullStr | Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. |
title_full_unstemmed | Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. |
title_short | Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. |
title_sort | evaluacion de la temperatura superficial en el puente vehicular primera de mayo con avenida boyaca de la ciudad de bogota |
topic | Cargas térmicas diferencias finitas, efectos térmicos - cámara térmica T48.23 R696e Thermal loads finite differences thermal effects - thermal camera |
url | http://repositorio.uan.edu.co/handle/123456789/7532 |
work_keys_str_mv | AT rodriguezestradamanuelangel evaluaciondelatemperaturasuperficialenelpuentevehicularprimerademayoconavenidaboyacadelaciudaddebogota AT gallomartinezjuandavid evaluaciondelatemperaturasuperficialenelpuentevehicularprimerademayoconavenidaboyacadelaciudaddebogota |