Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.

Bridges are subjected to temperature loads due to climatic action. However, Colombia lacks its own studies to quantify the design values of temperature loads on bridges. Consequently, in this work the objective is to monitor the surface temperature of a concrete bridge and it is carried out on the v...

Full description

Saved in:
Bibliographic Details
Main Authors: Rodriguez Estrada, Manuel Angel, Gallo Martinez, Juan David
Other Authors: Osorio Bustamante, Edison
Format: Trabajo de grado (Pregrado y/o Especialización)
Language:spa
Published: Universidad Antonio Nariño 2023
Subjects:
Online Access:http://repositorio.uan.edu.co/handle/123456789/7532
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1812647046009585664
author Rodriguez Estrada, Manuel Angel
Gallo Martinez, Juan David
author2 Osorio Bustamante, Edison
author_facet Osorio Bustamante, Edison
Rodriguez Estrada, Manuel Angel
Gallo Martinez, Juan David
author_sort Rodriguez Estrada, Manuel Angel
collection DSpace
description Bridges are subjected to temperature loads due to climatic action. However, Colombia lacks its own studies to quantify the design values of temperature loads on bridges. Consequently, in this work the objective is to monitor the surface temperature of a concrete bridge and it is carried out on the vehicular bridge of the First of May with Boyacá Avenue in Bogotá. Monitoring is carried out by measuring temperatures with a thermal camera at dawn and midday, for 15 days in two seasons of the year. Surface temperature data is presented at the top and bottom of the dashboard, providing values for future analysis and model calibration. In addition, a transient thermal balance model is performed using the finite difference method with hourly environmental data. The results are compared with the measurements, and it is concluded that the model can be a tool to reproduce the thermal phenomenon for future analyses
format Trabajo de grado (Pregrado y/o Especialización)
id repositorio.uan.edu.co-123456789-7532
institution Repositorio Digital UAN
language spa
publishDate 2023
publisher Universidad Antonio Nariño
record_format dspace
spelling repositorio.uan.edu.co-123456789-75322024-10-09T22:41:31Z Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá. Rodriguez Estrada, Manuel Angel Gallo Martinez, Juan David Osorio Bustamante, Edison Cargas térmicas diferencias finitas, efectos térmicos - cámara térmica T48.23 R696e Thermal loads finite differences thermal effects - thermal camera Bridges are subjected to temperature loads due to climatic action. However, Colombia lacks its own studies to quantify the design values of temperature loads on bridges. Consequently, in this work the objective is to monitor the surface temperature of a concrete bridge and it is carried out on the vehicular bridge of the First of May with Boyacá Avenue in Bogotá. Monitoring is carried out by measuring temperatures with a thermal camera at dawn and midday, for 15 days in two seasons of the year. Surface temperature data is presented at the top and bottom of the dashboard, providing values for future analysis and model calibration. In addition, a transient thermal balance model is performed using the finite difference method with hourly environmental data. The results are compared with the measurements, and it is concluded that the model can be a tool to reproduce the thermal phenomenon for future analyses Los puentes están sometidas a cargas de temperatura por la acción climática. Sin embargo, para Colombia faltan estudios propios para cuantificar los valores de diseño de cargas por temperatura en los puentes. En consecuencia, en este trabajo se plantea como objetivo el monitoreo de la temperatura superficial de un puente de concreto y se realiza sobre el puente vehicular de la Primera de Mayo con Avenida Boyacá en Bogotá. El monitoreo se efectúa midiendo las temperaturas con cámara térmica en horas del amanecer y del mediodía, durante 15 días en dos épocas del año. Se presentan los datos de temperatura superficial en la parte superior e inferior del tablero, aportando valores para futuros análisis y calibración de modelos. Además, se realiza un modelo transitorio de balance térmico mediante el método de diferencias finitas con datos ambientales horarios. Los resultados se comparan con las mediciones y se concluye que el modelo puede ser una herramienta para reproducir el fenómeno térmico para futuros análisis. Ingeniero(a) Civil Pregrado Presencial Monografía 2023-02-14T19:58:53Z 2023-02-14T19:58:53Z 2022-11-30 Trabajo de grado (Pregrado y/o Especialización) info:eu-repo/semantics/acceptedVersion http://purl.org/coar/resource_type/c_7a1f http://purl.org/coar/version/c_970fb48d4fbd8a85 http://repositorio.uan.edu.co/handle/123456789/7532 American Association of State Highway and Transportation Officials AASTHO-98 AASHTO, 2016. (2016). Knovel—AASHTO LRFD Bridge Design Specifications, U.S. Customary Units with 2015 and 2016 Interim Revisions (7th Edition). https://app.knovel.com/kn/resources/kpAASHTO6E/toc American National Standard Data Format for Radiation Detectors Used for Homeland Security—Redline. (2020). ANSI N42.42-2020 (Revision of ANSI N42.42-2012) - Redline, 1-311. Chile.cubica. (2017). Patologías en Construcción. chilecubica. http://www.chilecubica.com/patologías/ Díaz Barreiro, Patricia. (2014). Protocolo para los estudios de patología de la construcción en edificaciones de concreto reforzado en Colombia. https://repository.javeriana.edu.co/handle/10554/12694 Ding, K., Hu, P., & Xia, D. (2010). Research on Type Selection of Highway Bridge Composite Expansion and Contraction Installation. 2010 International Conference on E-Product E-Service and E-Entertainment, 1-4. https://doi.org/10.1109/ICEEE.2010.5660383 Google Maps. (2022). Google Maps. https://www.google.com/maps/@4.6188565,- 74.1400352,3a,75y,118.45h,84.62t/data=!3m7!1e1!3m5!1s6XTAlJ2pPVCEklKtXnv4kA!2e0!6s https:%2F%2Fstreetviewpixelspa.googleapis.com%2Fv1%2Fthumbnail%3Fpanoid%3D6XTAlJ2pPVCEklKtXnv4kA%26cb_cl ient%3Dmaps_sv.tactile.gps%26w%3D203%26h%3D100%26yaw%3D199.06444%26pitch%3D 0%26thumbfov%3D100!7i16384!8i8192 Heng, L., & Huarui, G. (2018). Analysis of Longitudinal Cracking for Hollow-core Slab Bridges. 2018 3rd IEEE International Conference on Intelligent Transportation Engineering (ICITE), 68-73. https://doi.org/10.1109/ICITE.2018.8492703 IDEAM. (2018). Consulta y Descarga de Datos Hidrometeorológicos. http://dhime.ideam.gov.co/atencionciudadano/ Invias. (2020). A partir de hoy, Gobierno Nacional pone en funcionamiento el Puente Hisgaura en Santander. https://www.invias.gov.co/index.php/sala/noticias/3655-a-partir-de-hoygobierno-nacional-pone-en-funcionamiento-el-puente-hisgaura-en-santander Liu, H. (2020). Sensitivity of Seismic Response of the Steel-Concrete Plate Composite Beam Bridge with Transverse Supported Steel Beams to Design Parameters. 2020 International Conference on Intelligent Transportation, Big Data & Smart City (ICITBS), 205-209. https://doi.org/10.1109/ICITBS49701.2020.00050 instname:Universidad Antonio Nariño reponame:Repositorio Institucional UAN repourl:https://repositorio.uan.edu.co/ spa Acceso abierto Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) https://creativecommons.org/licenses/by-nc-nd/4.0/ info:eu-repo/semantics/openAccess http://purl.org/coar/access_right/c_abf2 application/pdf application/pdf application/pdf Universidad Antonio Nariño Ingeniería Civil Facultad de Ingeniería Civil Bogotá - Sur
spellingShingle Cargas térmicas
diferencias finitas,
efectos térmicos - cámara térmica
T48.23 R696e
Thermal loads
finite differences
thermal effects - thermal camera
Rodriguez Estrada, Manuel Angel
Gallo Martinez, Juan David
Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
title Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
title_full Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
title_fullStr Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
title_full_unstemmed Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
title_short Evaluación de la temperatura superficial en el puente vehicular Primera de Mayo con Avenida Boyacá de la ciudad de Bogotá.
title_sort evaluacion de la temperatura superficial en el puente vehicular primera de mayo con avenida boyaca de la ciudad de bogota
topic Cargas térmicas
diferencias finitas,
efectos térmicos - cámara térmica
T48.23 R696e
Thermal loads
finite differences
thermal effects - thermal camera
url http://repositorio.uan.edu.co/handle/123456789/7532
work_keys_str_mv AT rodriguezestradamanuelangel evaluaciondelatemperaturasuperficialenelpuentevehicularprimerademayoconavenidaboyacadelaciudaddebogota
AT gallomartinezjuandavid evaluaciondelatemperaturasuperficialenelpuentevehicularprimerademayoconavenidaboyacadelaciudaddebogota
  • Editorial
  • CRAI
  • Repositorio
  • Libros