Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2)
In this work, it is proposed to carry out a design consisting of a glycol pumping station that works in cascade with a natural refrigerant such as CO₂, taking into account a smaller space ratio than the existing pumping station, which has been in operation for about 25 years. Service and operates by...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Trabajo de grado (Pregrado y/o Especialización) |
Language: | spa |
Published: |
Universidad Antonio Nariño
2022
|
Subjects: | |
Online Access: | http://repositorio.uan.edu.co/handle/123456789/6724 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1812647111772078080 |
---|---|
author | Cerón Bernal, José Francisco |
author2 | Hernández Vásquez, José Daniel |
author_facet | Hernández Vásquez, José Daniel Cerón Bernal, José Francisco |
author_sort | Cerón Bernal, José Francisco |
collection | DSpace |
description | In this work, it is proposed to carry out a design consisting of a glycol pumping station
that works in cascade with a natural refrigerant such as CO₂, taking into account a smaller
space ratio than the existing pumping station, which has been in operation for about 25 years.
Service and operates by pumping glycol in cascade with R717 ammonia.
The design incorporates several requests from the requesting company, such as
working with a new refrigerant in the industry such as R744 (CO₂), and that the pumping
station be adaptable to the demanded cooling load, that is, adapt the pumping capacity as
much as according the demand in real time. Thus reducing energy consumption, thus
contributing to being a sustainable and environmentally friendly company. |
format | Trabajo de grado (Pregrado y/o Especialización) |
id | repositorio.uan.edu.co-123456789-6724 |
institution | Repositorio Digital UAN |
language | spa |
publishDate | 2022 |
publisher | Universidad Antonio Nariño |
record_format | dspace |
spelling | repositorio.uan.edu.co-123456789-67242024-10-09T22:43:04Z Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) Cerón Bernal, José Francisco Hernández Vásquez, José Daniel Acosta Porras, Esnel Alexander Refrigerante R744 Estación de bombeo Carga frigorífica Sustentabilidad Keywords: R744 pumping station refrigeration load reduce consumption sustainability In this work, it is proposed to carry out a design consisting of a glycol pumping station that works in cascade with a natural refrigerant such as CO₂, taking into account a smaller space ratio than the existing pumping station, which has been in operation for about 25 years. Service and operates by pumping glycol in cascade with R717 ammonia. The design incorporates several requests from the requesting company, such as working with a new refrigerant in the industry such as R744 (CO₂), and that the pumping station be adaptable to the demanded cooling load, that is, adapt the pumping capacity as much as according the demand in real time. Thus reducing energy consumption, thus contributing to being a sustainable and environmentally friendly company. En este trabajo se propone realizar un diseño consistente en una estación de bombeo de glicol que trabaje en cascada con un refrigerante natural como el CO₂ teniendo en cuenta una relación de espacio menor a la estación de bombeo existente, la cual lleva en operación cerca de 25 años de servicio y opera bombeando glicol en cascada con R717 amoniaco. El diseño incorpora varias peticiones de la empresa solicitante como trabajar con un refrigerante nuevo en la industria, como lo es el R744 (CO₂) y que la estación de bombeo sea adaptativa a la carga frigorífica demandada, es decir, que pueda adaptar la capacidad de bombeo según la demanda en tiempo real así lograr disminuir el consumo energético contribuyendo así a ser una empresa sustentable y amigable con el entorno. Ingeniero(a) Electromecánico(a) Pregrado Distancia Monografía 2022-08-08T19:47:51Z 2022-08-08T19:47:51Z 2022-06-03 Trabajo de grado (Pregrado y/o Especialización) info:eu-repo/semantics/acceptedVersion http://purl.org/coar/resource_type/c_7a1f http://purl.org/coar/version/c_970fb48d4fbd8a85 http://repositorio.uan.edu.co/handle/123456789/6724 ACRLATINOAMERICA. (2018). soluciones con separadores de aire. Obtenido de www.acrlatinoamerica.com: https://www.acrlatinoamerica.com/201708237599/articulos/otrosenfoques/soluciones-con-separadores-de-aire.html AERMEC. (2016). VPF FLUJO PRIMARIO VARIABLE. Obtenido de global.aermec.com: https://global.aermec.com/site/wp-content/uploads/TF_VPF_ES.pdf Alfa Laval. (2022). www.alfalaval.com.co. Obtenido de intercambiadores-de-calor-deplacas: https://www.alfalaval.com.co/productos-y-soluciones/transferencia-decalor/intercambiadores-de-calor-de-placas/intercambiadores-de-calor-de-placassoldadas/ ALTERTECNIA. (s.f.). Uso de amoniaco o CO₂ en instalaciones frigoríficas: nuevas tendencias ecológicas. Obtenido de Altertecnia 2018: https://altertecnia.com/amoniaco-co%E2%82%82-instalaciones-frigorificas/ ASHRAE. (1 de Febrero de 2017). Documento de posición de ASHRAE sobre el Amoniaco como refrigerante. Obtenido de document: https://www.ashrae.org/file%20library/about/position%20documents/ammonia-asa-refrigerant-pd-2017.pdf BiografíasyVidas.com. (2004). Thomas Savery. Recuperado el 27 de 03 de 2022, de Biografías y Vidas: https://www.biografiasyvidas.com/biografia/s/savery.htm bombeo. (2022). bombeo.co. Obtenido de bombeo.co/media/docs: https://admin.bombeo.co/media/docs/b9787d7e-994f-eb11-9460-00155d512601.pdf Cengel, Y. A. (2004). Transferencia de calor y masa. Bogota: McGraw-Hill. Cengel, Y. A. (2006). Mecanica de Fluidos. Bogota: MacGraw-Hill. CHQUIMICA. (2021). Productos Quimicos. Recuperado el 26 de 03 de 2022, de Propilenglicol. instname:Universidad Antonio Nariño reponame:Repositorio Institucional UAN repourl:https://repositorio.uan.edu.co/ spa Acceso abierto Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) https://creativecommons.org/licenses/by-nc-nd/4.0/ info:eu-repo/semantics/openAccess http://purl.org/coar/access_right/c_abf2 application/pdf application/pdf application/pdf Universidad Antonio Nariño Ingeniería Electromecánica Facultad de Ingeniería Mecánica, Electrónica y Biomédica Cali Farallones |
spellingShingle | Refrigerante R744 Estación de bombeo Carga frigorífica Sustentabilidad Keywords: R744 pumping station refrigeration load reduce consumption sustainability Cerón Bernal, José Francisco Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) |
title | Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) |
title_full | Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) |
title_fullStr | Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) |
title_full_unstemmed | Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) |
title_short | Diseño de un sistema de bombeo de agua Glicolada para enfriadores de cavas de maduración usando refrigerante natural R-744 (CO2) |
title_sort | diseno de un sistema de bombeo de agua glicolada para enfriadores de cavas de maduracion usando refrigerante natural r 744 co2 |
topic | Refrigerante R744 Estación de bombeo Carga frigorífica Sustentabilidad Keywords: R744 pumping station refrigeration load reduce consumption sustainability |
url | http://repositorio.uan.edu.co/handle/123456789/6724 |
work_keys_str_mv | AT ceronbernaljosefrancisco disenodeunsistemadebombeodeaguaglicoladaparaenfriadoresdecavasdemaduracionusandorefrigerantenaturalr744co2 |