Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural
The main objective of this graduate work is to analyze the economic feasibility of incorporating seismic isolators in buildings located in Cucuta, Colombia. Considering its impact on the structural resilience to seismic events. The methodology included a cost comparison between a structure with an i...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Tesis/Trabajo de grado - Monografía - Pregrado |
Language: | Español |
Published: |
Universidad Antonio Nariño
2025
|
Subjects: | |
Online Access: | https://repositorio.uan.edu.co/handle/123456789/12553 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1831063287090905088 |
---|---|
author | Castro Muñoz, Johan Andrés |
author2 | Osorio , Edison |
author_facet | Osorio , Edison Castro Muñoz, Johan Andrés |
author_sort | Castro Muñoz, Johan Andrés |
collection | DSpace |
description | The main objective of this graduate work is to analyze the economic feasibility of
incorporating seismic isolators in buildings located in Cucuta, Colombia. Considering its impact
on the structural resilience to seismic events. The methodology included a cost comparison
between a structure with an isolated base and a structure with a conventional fixed base previously
designed under the Nsr-10 guidelines. In addition, an evaluation and comparison of structural
parameters and performance of both structures was performed. |
format | Tesis/Trabajo de grado - Monografía - Pregrado |
id | repositorio.uan.edu.co-123456789-12553 |
institution | Repositorio Digital UAN |
language | Español |
publishDate | 2025 |
publisher | Universidad Antonio Nariño |
record_format | dspace |
spelling | repositorio.uan.edu.co-123456789-125532025-03-03T17:28:24Z Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural Castro Muñoz, Johan Andrés Osorio , Edison Molina, Carlos Estructura Aislador Sismo Ingeniería Estructural Seguridad Estructural Resiliencia Sísmica Structure Isolator Earthquake Structural Engineering Structural Safety Seismic Resilience The main objective of this graduate work is to analyze the economic feasibility of incorporating seismic isolators in buildings located in Cucuta, Colombia. Considering its impact on the structural resilience to seismic events. The methodology included a cost comparison between a structure with an isolated base and a structure with a conventional fixed base previously designed under the Nsr-10 guidelines. In addition, an evaluation and comparison of structural parameters and performance of both structures was performed. El presente trabajo de grado tiene como objetivo principal analizar la viabilidad económica de la incorporación de aisladores sísmicos en edificaciones ubicadas en Cúcuta, Colombia. Considerando su impacto en la resiliencia estructural ante eventos sísmicos. La metodología incluyo la comparación de costos entre una estructura con base aislada y una con base fija convencional previamente diseñada bajo los lineamientos de la Nsr-10. Además, se realizó una evaluación y comparación de parámetros estructurales y resultados de ambas estructuras final Ingeniero(a) Civil Pregrado Presencial Monografía 2025-03-03T17:28:23Z 2025-03-03T17:28:23Z 2024-11-21 2025-03-03 Tesis/Trabajo de grado - Monografía - Pregrado Estudio descriptivo info:eu-repo/semantics/acceptedVersion http://purl.org/coar/resource_type/c_46ec http://purl.org/redcol/resource_type/PIC http://purl.org/coar/version/c_b1a7d7d4d402bcce https://repositorio.uan.edu.co/handle/123456789/12553 Español info:eu-repo/semantics/openAccess http://purl.org/coar/access_right/c_abf2 pdf application/pdf application/pdf application/pdf Universidad Antonio Nariño Ingeniería Civil Facultad de Ingeniería Civil Bogotá - Sur instname:Universidad Antonio Nariño Araque, Y. (2015). GUÍA PARA EL CÁLCULO DE LA FUERZA HORIZONTAL EQUIVALENTE Y DERIVAS SEGÚN TÍTULO A4-A6 NSR-10 YARELY DEL ROCIO ARAQUE CRISTANCHO UNIVERSIDAD MILITAR NUEVA GRANADA FACULTAD DE ESTUDIOS A DISTANCIA-FAEDIS PROGRAMA DE INGENIERÍA CIVIL. ASCE. (2012). Guía para la Implementación de Sistemas de Monitoreo Estructural. 1. Brewick, P. T., Johnson, E. A., Sato, E., & Sasaki, T. (2018). Constructing and evaluating generalized models for a base-isolated structure. Structural Control and Health Monitoring, 25(11). https://doi.org/10.1002/stc.2243 Cancellara, D., & De Angelis, F. (2014). A comparison of different base isolation systems for a multistorey reinforced concrete building. Civil-Comp Proceedings, 106. CDV Ingeniería Antisísmica. (2023, March). DISIPADORES SÍSMICOS DE FLUIDO VISCOSO. CDV Ingenieria. Cimellaro, G. P. (2013). Resilience-based design (RBD) modelling of civil infrastructure to assess seismic hazards. In Handbook of Seismic Risk Analysis and Management of Civil Infrastructure Systems. https://doi.org/10.1533/9780857098986.2.268 Clemente, P., & Buffarini, G. (2010). Base isolation: Design and optimization criteria. Seismic Isolation and Protective Systems, 1(1), 17–40. https://doi.org/10.2140/siaps.2010.1.17 CNN noticias. (2023, March 12). Turquía detiene a constructores por el derrumbe de edificios en los terremotos. Causas de Los Colapsos En El Sismo de Turquia. https://efe.com/mundo/2023-02- 13/investigacion-terremotos-turquia-y-siria/ CYPECAD - CYPE. (2024). https://info.cype.com/es/software/cypecad/ Dynamic Isolation Systems - Technical Information. (n.d.). Retrieved April 8, 2024, from https://www.disinc.com/technical.html |
spellingShingle | Estructura Aislador Sismo Ingeniería Estructural Seguridad Estructural Resiliencia Sísmica Structure Isolator Earthquake Structural Engineering Structural Safety Seismic Resilience Castro Muñoz, Johan Andrés Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural |
title | Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural |
title_full | Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural |
title_fullStr | Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural |
title_full_unstemmed | Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural |
title_short | Justificación Económica Para La Implementación De Un Dispositivo De Disipación De Energía Estructural |
title_sort | justificacion economica para la implementacion de un dispositivo de disipacion de energia estructural |
topic | Estructura Aislador Sismo Ingeniería Estructural Seguridad Estructural Resiliencia Sísmica Structure Isolator Earthquake Structural Engineering Structural Safety Seismic Resilience |
url | https://repositorio.uan.edu.co/handle/123456789/12553 |
work_keys_str_mv | AT castromunozjohanandres justificacioneconomicaparalaimplementaciondeundispositivodedisipaciondeenergiaestructural |